{"product_id":"tord4-63-2p-63a-10ma-a-ac-type-residual-current-circuit-breaker-rccb-rcd","title":"TORD4-63 2P 63A 10mA A\/AC Type Residual Current Circuit Breaker RCCB RCD","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e1.\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eProvides protection against earth fault\/leakage current and function of isolation.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e2.\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eHigh short-circuit current withstand capacity.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e3.\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eApplicable to terminal and pin\/fork type busbar connection.\u003c\/p\u003e\u003c!-- details --\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e4.\u003c\/strong\u003e Approved over-entering and down-entering connection.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e5.\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAutomatically disconnect the circuit when earth fault\/leakage current occurs and exceeds the rated sensitivity.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e6.\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003eIndependent of power supply and line voltage, and free from external interference, voltage fluctuation.\u003c\/p\u003e\n\u003cdiv class=\"woocommerce-tabs\"\u003e\n\u003cdiv id=\"tab-description\" class=\"panel entry-content\"\u003e\n\u003cdiv class=\"vc_row wpb_row vc_row-fluid\"\u003e\n\u003cdiv class=\"vc_span12 wpb_column vc_column_container\"\u003e\n\u003cdiv class=\"wpb_wrapper\"\u003e\n\u003cdiv data-scroll=\"on\" data-respwidth=\"400\" data-respmode=\"Tabs\" data-activebg=\"#4f90d1\" data-activeicon=\"\" data-activetitle=\"#ffffff\" data-animation=\"Slide\" data-responsivemode=\"Both\" data-rotatetabs=\"0\" data-titlehovercolor=\"#ffffff\" data-titlehoverbg=\"#4f90d1\" data-fullheight=\"off\" data-titlecolor=\"#74777b\" data-titlebg=\"#e7ecea\" data-tabsstyle=\"style1\" class=\"ult_tabs custome_table_size animated Slide delay-undefined\" id=\"advanced-tabs-desc-wrap-3834\"\u003e\n\u003cdiv class=\"ult_tabcontent ult-responsive style1\" data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' data-ultimate-target=\"#advanced-tabs-desc-wrap-3834 .ult_tabcontent .ult_tab_min_contain  p\"\u003e\n\u003cdiv class=\"ult_tab_min_contain\"\u003e\n\u003cdiv class=\"ult_tabitemname\"\u003e\n\u003cdiv class=\"wpb_text_column wpb_content_element\"\u003e\n\u003cdiv id=\"ct_yvvh5nb5udd12uel8gq7\" class=\"wpb_wrapper\"\u003e\n\u003cp\u003eResidual Current Circuit Breaker is applicable to electric circuits with rated voltage 230\/400V AC, frequency 50\/60Hz and rated current up to 125Amp.\u003cbr\u003eThe RCCB provides indirect protection to the operator’s body under such condition that the exposed live parts\u003cbr\u003eshould be connected to a proper earthing pole.The RCCB also provides protection against the fire danger caused\u003cbr\u003eby earth fault current due to function failure of over-current protection device.\u003cbr\u003e\u003cstrong\u003eSpecial tips:\u003c\/strong\u003e\u003cbr\u003e1. RCCB with rated sensitivity up to 10mA could be used as supplementary protecting device in case other\u003cbr\u003eprotecting device fails its protection against electric shock.\u003cbr\u003e2. RCCB designed for household installation and other similar application, is for non-professional operation,\u003cbr\u003eand no maintenance is required.\u003cbr\u003e3. RCCB provides on protection against electric shock resulted from direct contacts of both protected lines,or\u003cbr\u003eleakage current between these two lines.\u003cbr\u003e4. Particular devices such as surge protective devices,surge arrester etc are recommended to install at upstream line to RCCB as precaution against potential surge voltage and current occurring at its power input side.\u003cbr\u003e5. Satisfying conditions and applications as mentioned above,RCCB with “ON-OFF” indicating device is considered suitable for isolation function.\u003c\/p\u003e\n\u003cp\u003e1. Provides protection against earth fault\/leakage current and function of isolation.\u003c\/p\u003e\n\u003cp\u003e2. High short-circuit current withstand capacity.\u003c\/p\u003e\n\u003cp\u003e3. Applicable to terminal and pin\/fork type busbar connection.\u003c\/p\u003e\n\u003cp\u003e4. Approved over-entering and down-entering connection.\u003c\/p\u003e\n\u003cp\u003e5. Automatically disconnect the circuit when earth fault\/leakage current occurs and exceeds the rated sensitivity.\u003c\/p\u003e\n\u003cp\u003e6. Independent of power supply and line voltage, and free from external interference, voltage fluctuation.\u003c\/p\u003e\n\u003ctable class=\"cpxq\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Name\u003c\/td\u003e\n\u003ctd\u003eTORD4-63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eElectro-magnetic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Current characteristic:\u003c\/td\u003e\n\u003ctd\u003eA,AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole No:\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated making and breaking capacity\u003c\/td\u003e\n\u003ctd\u003e630A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current（A）\u003c\/td\u003e\n\u003ctd\u003e16, 25, 32, 40, 63, 80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e220V\/380V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated residual operating current |△(A):\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated residual non operating current |△ no:\u003c\/td\u003e\n\u003ctd\u003e0.5|△ n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated conditional short-circuit current inc:\u003c\/td\u003e\n\u003ctd\u003e3KA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated conditional residual short-circuit current |△c:\u003c\/td\u003e\n\u003ctd\u003e3KA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTripping duration:\u003c\/td\u003e\n\u003ctd\u003eInstantaneous tripping ≤0.1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual tripping current range:\u003c\/td\u003e\n\u003ctd\u003e0.5||△n~|△n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectro-mechanical endurance\u003c\/td\u003e\n\u003ctd\u003e≥4000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection capacity:\u003c\/td\u003e\n\u003ctd\u003eRigid conductor 25mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection terminal\u003c\/td\u003e\n\u003ctd\u003eScrew terminal\u003cbr\u003ePillar terminal with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFastening torque\u003c\/td\u003e\n\u003ctd\u003e2.0 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eOn symmetrical DIN rail 35mm\u003cbr\u003ePanel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-reviews\" class=\"panel entry-content\"\u003e\n\u003cdiv id=\"reviews\"\u003e\n\u003cdiv class=\"clear\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"clear\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cimg data-ll-status=\"loaded\" title=\"TORD4-63 RCCB DIMEMSIONS\" alt=\"TORD4-63 RCCB DIMEMSIONS\" height=\"365\" width=\"830\" src=\"https:\/\/www.elcb.net\/wp-content\/uploads\/2017\/03\/TORD4-63-RCCB-DIMEMSIONS-01.jpg\" class=\"vc_single_image-img lazyloaded\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"clear\"\u003eProduct Source: \u003ca href=\"https:\/\/www.elcb.net\/product\/tord4-63-2p-63a-10ma-electronic-type-residual-current-circuit-breaker-rccb-rcd\/\" target=\"_blank\" rel=\"noopener noreferrer\"\u003ehttps:\/\/www.elcb.net\/product\/tord4-63-2p-63a-10ma-electronic-type-residual-current-circuit-breaker-rccb-rcd\/\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\u003c!--\n.tb_button {padding:1px;cursor:pointer;border-right: 1px solid #8b8b8b;border-left: 1px solid #FFF;border-bottom: 1px solid #fff;}.tb_button.hover {borer:2px outset #def; background-color: #f8f8f8 !important;}.ws_toolbar {z-index:100000} .ws_toolbar .ws_tb_btn {cursor:pointer;border:1px solid #555;padding:3px}   .tb_highlight{background-color:yellow} .tb_hide {visibility:hidden} .ws_toolbar img {padding:2px;margin:0px}\n--\u003e\u003c\/style\u003e","brand":"TONGOU","offers":[{"title":"Default Title","offer_id":37318100451484,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0503\/6412\/1244\/products\/TORD4-632P63A10mAA_ACTypeResidualCurrentCircuitBreakerRCCBRCD5.jpg?v=1609199884","url":"https:\/\/eastsupplier.cn\/products\/tord4-63-2p-63a-10ma-a-ac-type-residual-current-circuit-breaker-rccb-rcd","provider":"EastSupplier Platform","version":"1.0","type":"link"}