{"product_id":"tord6b-63-2pole-type-b-rcd-16a-63a-30ma-residual-current-circuit-breaker-rccb","title":"TORD6B-63 2Pole Type B RCD 16A-63A 30mA Residual Current Circuit Breaker RCCB","description":"\u003cp\u003eType B RCCBs, in addition to normal AC, can detect high frequency AC and pure DC earth leakage currents. Reducing the risk of fire and\/or electrocution through automatic disconnection of the electrical supply relies on the selection of the correct type of RCCB. \u003c\/p\u003e\n\u003c!-- details --\u003e\n\u003cp\u003eType B RCCBs, in addition to normal AC, can detect high frequency AC and pure DC earth leakage currents. Reducing the risk of fire and\/or electrocution through automatic disconnection of the electrical supply relies on the selection of the correct\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.elcb.net\/rccb\/\"\u003e\u003cstrong\u003e\u003cem\u003etype of RCCB\u003c\/em\u003e\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cem\u003eApplications requiring ‘B’ types include:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eEV \u0026amp; PV installations\u003cbr\u003eFrequency converters\u003cbr\u003eUPS installations\u003cbr\u003eHigh-frequency power converters\u003cbr\u003eBuilding site power supply cabinets\u003c\/p\u003e\n\u003ctable class=\"cpxq\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"bold-head\"\u003e\n\u003ctd\u003eMain\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eResidual current circuit breaker(RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice application\u003c\/td\u003e\n\u003ctd\u003eElectrical vehicle charger, Solor energy system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles description\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork type\u003c\/td\u003e\n\u003ctd\u003eAC, Plusting DC, Smooth DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-leakage sensitivity\u003c\/td\u003e\n\u003ctd\u003e30mA, 100mA, 300mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth-leakage protection class\u003c\/td\u003e\n\u003ctd\u003eType B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bold-head\"\u003e\n\u003ctd\u003eComplementary\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice location in system\u003c\/td\u003e\n\u003ctd\u003eGroup incomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated breaking and making capacity\u003c\/td\u003e\n\u003ctd\u003eIm 630A, Idm 630A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated conditional short-circuit current\u003c\/td\u003e\n\u003ctd\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Ui] rated insulation voltage\u003c\/td\u003e\n\u003ctd\u003e250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e[Uimp] rated impulse withstand voltage\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eToggle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting mode\u003c\/td\u003e\n\u003ctd\u003eClip-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting support\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical durability\u003c\/td\u003e\n\u003ctd\u003e20000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e15000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening torque\u003c\/td\u003e\n\u003ctd\u003e3.5N.m(top or bottom)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bold-head\"\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 61008-1, IEC 61008-1, IEC\/EN 62423\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP40 for modular enclosure conforming to IEC 60529\u003cbr\u003eIP20 conforming to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature for operation\u003c\/td\u003e\n\u003ctd\u003e-25°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature for storage\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eProduct source: \u003ca href=\"https:\/\/www.elcb.net\/product\/tord6b-63-2pole-type-b-rcd-16a-63a-30ma-residual-current-circuit-breaker-rccb\/\" target=\"_blank\" rel=\"noopener noreferrer\"\u003ehttps:\/\/www.elcb.net\/product\/tord6b-63-2pole-type-b-rcd-16a-63a-30ma-residual-current-circuit-breaker-rccb\/\u003c\/a\u003e\u003c\/p\u003e","brand":"TONGOU","offers":[{"title":"Default Title","offer_id":37312935231644,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0503\/6412\/1244\/products\/TORD6B-632PoleTypeBRCD16A-63A30mAResidualCurrentCircuitBreakerRCCB5.jpg?v=1609158097","url":"https:\/\/eastsupplier.cn\/products\/tord6b-63-2pole-type-b-rcd-16a-63a-30ma-residual-current-circuit-breaker-rccb","provider":"EastSupplier Platform","version":"1.0","type":"link"}